When Reactor cannot see

If a provider stops reporting a key at all — the hardware dropped off the controller — Reactor holds the last known state and reports Ready=False with StateKeyUnavailable rather than treating lost visibility as a condition that ended (what to do about it).

Everything here was built against one setup, and this table says which one. “Verified” means a real capture or a real cluster; “expected” means the code path is version-independent as far as anyone can tell, which is not the same thing.

Verified Expected to work Known not to work
UniFi Network 10.5.67 10.x —
Console UDM Pro (gateway firmware 5.1.26) UDM/UDM SE/UDR/UXG, Cloud Key with a gateway adopted. A site with no gateway and no UniFi UPS now observes the fleet keys — devices, wifi and whichever of firmware/temperature/poe the hardware reports — but none of wan, isp or ups a site with nothing adopted at all: nothing to observe
UPS UniFi UPS 2U (USWDA26, firmware 1.6.1) any UniFi UPS reporting vbms_table third-party UPS over NUT — a separate provider, not this one
Kubernetes CI: envtest 1.36 API server, and the current kind default node image for e2e 1.25+ — only long-stable APIs are used (apps/v1 scale, policy/v1, apiextensions/v1, leases) —
Helm 3.x — —

Reactor asks the console what it is running and says so at startup:

Terminal window
kubectl -n reactor-system logs deploy/reactor | grep -E 'version detected|tested against'
# INFO UniFi Network version detected version=10.5.67 verifiedAgainst=10.5.67 verifiedConsole="UDM Pro"
# INFO Kubernetes version detected version=v1.34.1

Outside the range above it warns and carries on. Refusing to start against a console that would have worked fine is a worse failure than a log line, and most of them will work fine — the warning exists so that a missing state key reads as an incompatibility rather than as a configuration mistake. If your console is not in the table and it works, say so: every row here started as somebody’s report.

State keys degrade one at a time, so a console with no UniFi UPS still reports wan and isp, and a gateway whose fields have moved still reports ups. That holds across endpoints too: an observation reads stat/device and stat/health, and a console that answers one but not the other publishes the keys it can. Only observing nothing at all is an error.

Three keys are parsed against a documented shape, not a capture

Section titled “Three keys are parsed against a documented shape, not a capture”

Every parser here is written against a real captured response — except three, and this is where that is said plainly rather than in a commit message:

Key Fields it needs Status
firmware upgradable, upgrade_to_firmware, model_in_eol no capture contains them. The committed records carry version and nothing else about upgrades
temperature has_temperature, overheating, temperatures[], general_temperature no capture contains them. The UniFi UPS 2U reports no thermals at all
poe total_max_power, port_table[].poe_power no capture contains them. No switch record exists in this repository

They are written to the shape UniFi’s own API documents, every field is in the capture allowlist so the next real capture settles them, and each fails by publishing nothing rather than by publishing a reassuring value: no upgradable anywhere means no firmware key, not current; no thermals means no temperature key, not normal; an unreadable switch is left out rather than counted as having headroom.

If you run a UniFi switch or an access point, ./hack/capture-unifi.sh now writes stat-device-switch.json and stat-device-ap.json, and one of each would settle all three at once.

outlet.<n> is the opposite case and is listed here so the contrast is not lost: every field it reads — index, name, relay_state, relay_group — is in the committed capture, and the parser is written against real bytes. What is unverified about outlets is not the reading but the writing, which is why there is none.

Parsers are written against real captured API responses committed to testdata/, never against assumed formats. Two things worth stating plainly.

A genuine WAN failover has now been observed (#34, closed as verified). On 2026-08-18 the primary uplink was physically unplugged for 75 seconds and the console failed over to a cellular backup and back: wan moved from primary to backup and back to primary, and an Automation watching it claimed its target, scaled a Deployment to zero, and restored it to the replica count it held before, from the baseline annotation. The more interesting finding is which signal did the work. is_uplink — the signal of record — did not resolve the failover and structurally cannot on this hardware: a cellular uplink’s record carries no is_uplink field at all, so across the whole outage the log read is_uplink does not name a single live WAN port, and the gateway’s own uplink interface name — written as a fallback — is what produced backup. On cellular hardware that fallback is not a fallback; it is the only signal that answers. What remains unobserved is a wired-to-wired failover: that gateway’s second wired WAN has nothing plugged into it, so the only failover it can produce goes to cellular, and whether is_uplink moves cleanly when one wired port takes over from another is a question no hardware on hand can answer. The disagreement warnings still exist for exactly that reason, and the capture runbook is still how a wired-to-wired failover would be captured.

And the webhook fast path has been exercised against the mock console, not a real one — which is a large part of why it defaults off and why nothing depends on it being right.