UPS outlet state keys

outlet.<n> is the position of one mains relay

Section titled “outlet.<n> is the position of one mains relay”

A UniFi UPS reports one entry per switchable outlet, and Reactor publishes one key each — on while the relay is closed and delivering mains, off when it is not:

when:
provider: unifi
state:
outlet.nas: off # something cut power to the NAS

Switching one is a separate thing with its own guards: unifi.outlet.cut and unifi.outlet.restore. Observing has no guards and needs none — this key appears the moment a UPS with an outlet table is adopted, and reading a relay costs nothing.

The relay grouping, and what it turned out to mean

Section titled “The relay grouping, and what it turned out to mean”

The capture shows outlets 1–4 reporting relay_group: 1 and outlets 5–8 reporting relay_group: 2:

{"index": 1, "name": "Outlet 1", "relay_state": true, "relay_group": 1}

That grouping is why switching was deferred for as long as it was. If the relay group had been what the hardware switches, then “turn off outlet 3” would have meant “cut outlets 1 to 4”, and one of those may be carrying your gateway, your switch or your storage.

It is not. On 2026-08-15 outlet 8 was set to off on real hardware and outlets 5, 6 and 7 — which share its relay group — stayed on. outlet_caps decodes with one extra capability bit on outlets 1–4, exactly where the hardware documents four battery-backed and four surge-only outlets. So relay_group partitions outlets by what they can do, not by what switches together, and the outlets switch individually.

Reactor still prints the grouping when it first sees it, and still says what moved together whenever a relay does — because a second UPS model is not obliged to behave like the first one:

Terminal window
kubectl -n reactor-system logs deploy/reactor | grep unifi-outlets
# A UPS is reporting switchable outlets. On the hardware this was tested against
# they switch INDIVIDUALLY and the relay group below is a capability split ...
# device=ups-2u relayGroups="1=[outlet.1 outlet.2 outlet.3 outlet.4] 2=[outlet.5 ...]"
# Outlet state changed. If you are checking whether this ups switches an outlet
# or a whole bank, this line is the readout
# moved=outlet.5=on->off relayGroup=2 movedInGroup=1 outletsInGroup=4
# verdict="outlets in this group moved independently of each other"

Confirm it on your own hardware before allowlisting anything for unifi.outlet.cut. Toggle one outlet by hand — pick one in the bank carrying nothing you care about — and read that second line. movedInGroup=1 of 4 is the answer this hardware gave; 4 of 4 would mean your UPS switches a whole bank and must not be pointed at these actions. Both are rehearsable without hardware; see the mock.

Out of the box every outlet is called Outlet 1 … Outlet 8, which is the index spelled out rather than a name, so the key falls back to the index: outlet.3. Name them in the UniFi UI and the key becomes the name — NAS publishes outlet.nas.

Do it before writing anything against them. outlet.3 means something different the day somebody re-plugs the rack, and this is the same argument that made portName required rather than optional for unifi.poe.cycle: hardware that carries mains power should be addressed by what it is, not by where it happens to be plugged.

For switching, it is not advice: an outlet still carrying the placeholder is refused. Naming it is the only moment anybody writes down what the socket feeds, and the UPS itself will never tell you.

Renaming an outlet makes its old key vanish rather than report off, which Reactor treats as lost visibility — the last known state is held and Ready=False reports StateKeyUnavailable, so nothing sheds load because you labelled a socket. Two outlets addressed the same way publish neither, for the same reason two devices sharing a slug do.

These keys appear only when an adopted device actually lists outlets. The captured gateway reports "outlet_table": [], so having the field is not the same as having outlets, and an outlet that reports no relay_state publishes nothing at all rather than being read as off.

If more than one adopted device reports an outlet table, only the first is published — outlet indexes restart on every chassis, so merging them would put one device’s outlet under another’s key. Switching an outlet on the second device still works, because an outlet action names its UPS by MAC.

They are also not in reactor_state_info, and the reasoning is worth separating from device.<name>’s, because only half of it carries over — see Cardinality.