Power and UPS state keys

ups and ups.battery are separate on purpose. An automation matching ups: on-battery stays matched for the whole outage as the battery drains — with a single escalating enum, dropping from on-battery to low-battery would leave the matching state and fire onExit, scaling workloads back up in the middle of a power failure. Express escalation by matching both keys instead; all keys in a state block must match.

when:
provider: unifi
state:
ups: on-battery
ups.battery: critical

Charge is a poor shutdown trigger; runtime is a better one

Section titled “Charge is a poor shutdown trigger; runtime is a better one”

ups.battery ignores load, and load is most of the answer: 30% at 300W and 30% at 900W are very different situations. ups.runtime is the UPS’s own estimate of how long it can carry what is plugged into it right now, bucketed against thresholds you configure, and it is what a shutdown automation should actually match on.

when:
provider: unifi
state:
ups: on-battery
ups.runtime: critical # not "the battery is low" — "we are about to run out"

ups.load is the other half of the same picture: the draw as a fraction of the UPS’s power budget. It is what tells you why the runtime is short, and it is worth matching before an outage rather than during one — a UPS already running at 85% has no headroom to give you when the power goes.

It is published on mains as well as on battery, deliberately. “Could we even survive an outage right now” is a question worth being able to ask while the lights are still on.

Both are separate keys for the same reason ups.battery is: they are independent axes, and an automation matching one must not stop matching because another moved. All four UPS keys are only published when a UniFi UPS is adopted, and ups.runtime and ups.load are additionally omitted when the UPS reports no runtime estimate or no usable power figures — a missing measurement is never turned into a value.

⚠️ timeToRemain’s unit is inferred to be seconds, from a single observation on a UPS that was not discharging. Nothing in Reactor depended on it before this key existed. Confirm it against a real outage before letting ups.runtime: critical shut anything down — #7 has the procedure.